İs as follows the output of these commands:
maintenance hardware list
maintenance problems show
confirm shell zpool status
confirm shell zpool list
maintenance hardware show
We have a memory problem in Exalogic ZFS Storage cel01 node.
Details appearing on the ilom are as follows;
İlom > Maintenance > Problems
Description Multiple correctable ECC errors on a memory DIMM have been detected.
Type Minor Fault
Impact The system will continue to operate in the presence of this fault. The memory DIMM is still in use and is not disabled. The memory DIMM is disabled on next system reboot and remains unavailable until repaired. System performance may be impacted slightly due to retired memory pages.
Affected components
100% sp000exl-cel01: DIMM 1/10 (in service)View component in hardware view
Manufacturer: Samsung
Part name: 07075400,M393A2G40EB1-CRC
Model number: 16384MB DDR4 SDRAM DIMM
Serial number: 00CE03175021612A98
Event time 2020-3-29 13:31:46
Error Codes
—————————————————
Multiple correctable ECC errors on a memory DIMM have been detected.
Problem Category/Subcategory
—————————————————
Storage Issues (ZS Array/ZFS Appliance/NAS)
Uploaded Files
—————————————————
Template Question Responses
—————————————————
1) Issue
<<<Internal_Use–AutoDX:event code:USD-HW-MEM>>>
2) <<<Internal_Use–AutoDX:input: Enclosure type
Not listed above
3) location of disk
sp000exl-cel01: DIMM 1/10 (in service) View component in hardware view
4) model of disk
Manufacturer: Samsung
Part name: 07075400,M393A2G40EB1-CRC
Model number: 16384MB DDR4 SDRAM DIMM
Serial number: 00CE03175021612A98
5) When are you planning to actually schedule the replacement activity?
As Soon As Possible
6) Specific date and time for the replacement activity (Time zone will be derived from this SR’s service address).
FİX Please use the following procedure: To log in remotely using the CLI, use an ssh client. If you have not configured other users to administer the appliance, you will need to log in as root. When you log in, the CLI will present you with a prompt that consists of the hostname, followed by a colon, followed by a greater-than sign: % ssh root@dory Password: Last login: Mon Oct 13 15:43:05 2009 from kiowa.sf.fishpo dory:> When navigating through the CLI, there are two principles to be aware of: Tab completion is used extensively – if you are not sure what to type in any given context, pressing the Tab key will provide you with possible options. Throughout the documentation, pressing Tab is presented as the word “tab” in bold italics. Help is always available – the help command provides context-specific help. Help on a particular topic is available by specifying the topic as an argument to help, for example help commands. Available topics are displayed by tab-completing the help command, or by typing help topics. You can combine these two principles, as follows: dory:> help tab builtins commands general help properties script https://docs.oracle.com/cd/E27998_01/html/E48433/user_interface__cli.html Run the second part: B. reset SP from the CLI of the appliance: appliance:> maintenance hardware appliance:maintenance hardware> select chassis-000 appliance:maintenance chassis-000> select sp appliance:maintenance chassis-000 sp> reset This will restart the service processor Are you sure? (Y/N) After this please FMA logs on the ILOM, you can use the bellow document: Doc ID 1381773.1 – How to clear FMA logs on the ILOM or Solaris on x86 platforms al last upload a full ILOM snapshot in order to check if there are any active faults, you can use the bellow document: Doc ID 1020204.1 – Collecting snapshot on ILOM 3.x and later platforms As listed previously by you please connect to that node and perform the mark as repair. The login must be done with root and the set pasword. You might also like: Exalogic IB Ports State Shown as Down Have a nice day. |